Hp usb key linux

Proliant Maintenance CD

HP USB key utility

The HP USB Key Utility enables you to copy the Firmware Maintenance CD contents to a USB memory key. You can then run the Firmware Maintenance applications from a USB key instead of from the CD. Insert a USB key containing the Firmware CD ISO image created by using the HP USB Key Creator for Windows utility into a usb port of your server or through the SUV (Serial-USB-Video) cable attached to the server to be updated if the server supports the SUV cable.

For WindowsВ® operating systems, the HP USB Key Creator for Windows utility must be downloaded from the HP website and installed on a workstation. After installation, the utility places a shortcut in the HP System Tools folder in the Programs start menu.

To create your bootable drive key and copy the contents of the CD:

  1. Place your HP USB drive key in an available USB port.
  2. Select the HP USB Key Utility shortcut in the HP System Tools folder.
  3. Complete each step presented by the application.
  4. The HP USB Key Creator formats the USB key, therefore files on the key are lost. Ensure that you are using a USB key that is at least 1GB in size and does not contain any valuable files.

For Linux, the USB key can be created manually:

  1. Obtain SYSLINUX 3.2 or higher from freshmeat.net or syslinux.zytor.com and download to a Linux workstation.
  2. Install the SYSLINUX RPM obtained in step 1.
  3. Create a directory for the USB key mountpoint, if one does not already exist.

For example, mkdir /usbkey.
Insert the USB key and mount it. The device mountpoint can vary depending on whether other SCSI drives are also installed on the server. Therefore, the device mountpoint can be sdb1, sdc1, and so forth.

mount /dev/sda1 /usbkey

  • Issue the command ./syslinux /usbkey to have SYSLINUX write out the boot partition to the USB key. Failure to issue this command might lead to a key that does not boot the Firmware CD until the SYSLINUX command is successful.
  • Create a directory to mount the CD image. For example, mkdir /cd_mount_point.
  • Insert the Firmware CD or mount the Firmware CD ISO through a loopback:

    mount /dev/cdrom /cd_mount_point or mount -t iso9660 firmware- .iso /cd_mount_point -o loop
    Change to the /usb directory on the CD.

    Источник

    Hp usb key linux

    The information contained herein is subject to change without notice. The only warranties for Hewlett Packard Enterprise products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. Hewlett Packard Enterprise shall not be liable for technical or editorial errors or omissions contained herein.

    Confidential computer software. Valid license from Hewlett Packard Enterprise required for possession, use, or copying. Consistent with FAR 12.211 and 12.212, Commercial Computer Software, Computer Software Documentation, and Technical Data for Commercial Items are licensed to the U.S. Government under vendor’s standard commercial license.

    Links to third-party websites take you outside the Hewlett Packard Enterprise website. Hewlett Packard Enterprise has no control over and is not responsible for information outside the Hewlett Packard Enterprise website.

    Using the HPE USB Key Utility

    The HPE USB Key Utility is a Windows application that copies Intelligent Provisioning or HPE SPP contents, and other CD or DVD images to a USB flash drive. After copying data to the USB flash drive, you can run Intelligent Provisioning or SPP from the USB flash drive instead of from a CD or DVD. This process is beneficial in headless-server operations. It also simplifies the storage, transportation, and usage of the contents by allowing you to retrieve their images from the web and customize them as needed.

    Features

    The USB Key Utility supports:

    ISO files larger than 1 GB.

    Quick Formatting on USB flash drives.

    USB flash drives up to a maximum of 32 GB. USB flash drives larger than 32 GB are not displayed in the utility.

    Prerequisites

    Installing applications onto a USB flash drive requires a supported source CD, DVD, or ISO, and a USB flash drive with adequate storage space for storing the source contents. The USB Key Utility requires a USB 2.0 flash drive with a storage size larger than the media or ISO image (2 GB or greater).

    NOTE: Version 2.0 and later of the USB Key Utility does not support a 32-bit operating system. Use version 1.8 of the utility in 32-bit environments.

    AutoRun files

    AutoRun files do not start automatically from the utility. To start an AutoRun file, double-click the autorun.exe file in the appropriate CD or DVD folder on the USB Key.

    Creating a bootable USB key

    Installing the utility adds a shortcut in HPE System Tools in the Programs Start menu folder.

    To create a bootable USB key:

    Double-click the HPE USB Key Utility shortcut in the HPE System Tools folder.

    Complete each step as presented by the application:

    Click Next at the splash screen.

    Read the End-User License Agreement, and then select Agree and click Next .

    Select Create a bootable USB key from CD/DVD , and then click Next .

    NOTE: Do not select the Add an additional CD/DVD to a bootable USB key option with HP SUM 6.2.0, SPP 2014.02.0, or Intelligent Provisioning 1.60 and later, which no longer support multiple-boot environments on a single device.

    Place the USB flash drive in an available USB port. Insert the media in the optical drive or mount the ISO image, and then click Next .

    Choose the drive letter of the source, choose the drive letter of the target USB flash drive, and click Next .

    TIP: Click Rescan Target if you don’t see your drive key or just insert a new one.

    CAUTION: All data on the target USB key will be deleted.

    Click Next on the warning message screen. The USB flash drive is formatted, and the source contents are copied to the USB flash drive.

    Click Finish to display the README.TXT file.

    Adding additional content to a bootable USB key

    The USB Key Utility supports multiple images on a single USB flash drive if there is adequate space available on the USB flash drive and you are not loading content that works with a UEFI bootloader, which does not support multiple images due to security reasons.

    NOTE: HP SUM 6.2.0, SPP 2014.02.0, or Intelligent Provisioning 1.60 and later no longer support multiple-boot environments on a single device. HP SUM, SPP, and Intelligent Provisioning contain signed parts to work with the UEFI bootloader. This change no longer allows for multi-boot setups on a single device, such as a USB key.

    Follow the instructions for creating a bootable USB key.

    Double-click the HPE USB Key Utility shortcut in the HPE System Tools folder.

    Complete each step presented by the application:

    Click Next at the splash screen.

    Select Agree , and then click Next after reading the End-User License Agreement.

    Select Add an additional CD/DVD to a bootable USB key , and then click Next .

    Place the USB flash drive in an available USB port. Insert the media into the optical drive or mount the ISO image, and then click Next .

    Choose the drive letter of the source, choose the drive letter of the target USB flash drive, and then click Next .

    Click Next on the informational screen. The source contents are copied to the USB flash drive.

    Click Finish to display the README.TXT file.

    Repeat steps 2-3 for each source media or image to be transferred to the USB key.

    Источник

    Linux Mint Forums

    Welcome to the Linux Mint forums!

    Linux Mint 17 Not Booting On HP 6730b Via USB Key

    Linux Mint 17 Not Booting On HP 6730b Via USB Key

    Post by digiPixel » Sat May 31, 2014 10:35 pm

    Have a HP 6730b laptop that I am trying to install Linux Mint 17 on via USB Key. When booting the laptop it is frozen on the BIOS splash screen. Tried plugging the USB key into all of the laptop’s USB ports but still end up with the same result. Had even gone so far as booting from DVD but ran into the same issue. Thought that resetting the BIOS settings to their defaults might fix the issue however it made no difference.

    Would like to try booting via the Netboot method but I am stuck on how to extract the required files off the Linux Mint 17 ISO in order to get Netboot to work. Currently following the Netboot instructions on the Ubuntu website. Can someone please provide up to date instructions on doing a Netboot installation of Linux Mint 17.

    Re: Linux Mint 17 Not Booting On HP 6730b Via USB Key Quote

    Post by digiPixel » Sun Jun 01, 2014 6:49 pm

    Re: Linux Mint 17 Not Booting On HP 6730b Via USB Key

    Post by anthony_philipp » Sat Oct 18, 2014 5:22 pm

    I have the same laptop, an HP 6730b. I too have freezing issues if I try to boot off of the USB key. I tried recreating your steps above with the USB key, but it just boots right to windows. Is the only way to install to use the actual physical DVD drive? Thanks for any clarification, and thanks for posting your helpful steps.

    Re: Linux Mint 17 Not Booting On HP 6730b Via USB Key

    Post by digiPixel » Thu Oct 23, 2014 5:49 pm

    Re: Linux Mint 17 Not Booting On HP 6730b Via USB Key

    Post by anthony_philipp » Sat Oct 25, 2014 4:21 pm

    Thanks for the response! I’ll try to dig up a blank CD.

    You’re right that it is odd that Xubuntu loads, but Linux Mint doesn’t. I may wait just a touch longer to test Linux Mint 18 and see if that makes a difference. I appreciate the help!

    Re: Linux Mint 17 Not Booting On HP 6730b Via USB Key

    Post by anthony_philipp » Sat Nov 15, 2014 3:25 pm

    I was able to get it loaded by USB key using a different USB key. It is a 4GB verbatim USB drive, whereas originally I was using an unknown drive branded from a company I met at a conference. I don’t know why that would make the difference, but it appeared to solve the issue.

    Источник

    Hp usb key utility – HP ProLiant Support Pack User Manual

    Page 18

    Onboard Administrator firmware, select the Force downgrade box from the Firmware Information section on
    the Onboard Administrator GUI screen. Select the firmware file by browsing locally or by locating a URL
    using the input boxes. For any limitations in using older Onboard Administrator firmware or other

    downgrade options, see the Onboard Administrator User Guide.

    HP USB key utility

    The HP USB Key Utility enables you to copy the HP Smart Update Firmware DVD contents to a USB

    memory key. You can then run the Firmware update applications from a USB key instead of the DVD.
    Insert a USB key containing the Firmware DVD ISO image created by using the HP USB Key Creator for

    Windows® utility into a server USB port or the SUV (Serial-USB-Video) cable attached to the blade.
    For Windows® operating systems, the HP USB Key Creator for Windows® utility must be downloaded
    from the HP website (

    ) and installed on a workstation. After installation, the utility

    places a shortcut in the HP System Tools folder in the Programs start menu.
    To create your bootable drive key and copy the contents of the DVD:

    Insert the HP USB drive key in an available USB port.

    Select the HP USB Key Utility shortcut in the HP System Tools folder.

    Complete each step presented by the application.

    The HP USB Key Creator formats the USB key. Ensure that you are using a USB key that is at least
    1GB in size and does not contain any valuable files.

    For Linux, the USB key can be created manually:

    Obtain SYSLINUX 3.75 or higher from http://www.syslinux.zytor.com (

    and download it to a Linux workstation.

    Install the SYSLINUX RPM obtained in step 1.

    If a directory does not already exist, create one for the USB key mount point, for example, mkdir

    Insert the USB key, and then mount it. The device mount point might vary, depending on whether
    other SCSI drives are also installed on the server. Therefore, the device mount point can be sdb1,
    sdc1, and so on.
    mount /dev/sda1 /usbkey

    Use the ./syslinux /usbkey command to write out the boot partition to the USB key. Failure to

    run this command might lead to a key that does not boot the Firmware DVD until the SYSLINUX

    command is successful.

    Create a directory to mount the DVD image, for example, mkdir /cd_mount_point.

    Insert the Firmware DVD or mount the Firmware DVD ISO through a loopback:
    mount /dev/cdrom /cd_mount_point or mount -t iso9660 firmware-

    .iso /cd_mount_point -o loop

    Change to the /usb directory on the DVD:
    cd /cd_mount_point/usb

    Источник

    Практика: Как настроить сервер HP ProLiant ML10v2 и подготовить его к установке ОС

    Добрый день, дорогие друзья! Сегодня я хочу представить вам короткий практический обзор, посвященный решению конкретной задачи. А именно первоначальной настройке сервера и установке ОС Windows Server 2012 R2 с помощью фирменных средств развертывания HPE. Делать это я буду на примере популярного сейчас сервера HP ProLiant ML10v2 в следующей конфигурации (парт-номер 814483-421):

    • Башенный сервер 4U
    • Процессор Intel Pentium G3240
    • Встроенный RAID-контроллер HP Dynamic SmartArray B120i
    • В нашем случаем используются 4 диска Seagate LFF — они не входят в комплект самого сервера

    Полные характеристики можно посмотреть здесь.

    Особенность этого сервера, являющегося самым бюджетным представителем семейства ProLiant — отсутствие встроенных средств развертывания Intelligent Provisioning на самом сервере. Поэтому для его первоначальной настройки нужно использовать загрузочную флешку с образом HP Service Pack for ProLiant. Инструкция ниже будет включать в себя такие операции:

    • Подготовка и создание загрузочной флешки (обратите внимание, что работу с Service Pack for ProLiant также можно проделать из удаленной консоли iLO (http://h20564.www2.hpe.com/hpsc/swd/public/detail?swItemId=MTX_4f842ceb31cf48d392e22705a8), смонтировов ISO-образ оттуда
    • Настройка RAID на сервере
    • Обновление программных компонентов сервера (прошивок)
    • Установка ОС Windows Server 2012R2

    Все значимые операции сопровождаются картинками. Ужасное качество картинок служит для достижения эффекта присутствия 🙂

    Подготовка и создание загрузочной флешки

    Итак, вы стали счастливым обладателем сервера HP ProLiant ML10v2 (или готовите его к продаже). Перед началом его настройки вам нужно проделать следующие операции:

      Найдите флешку 8ГБ или больше.

    Подготовьте диск с дистрибутивом ОС и лицензионный ключ. В моем примере в сервере не было встроенного DVD-привода, поэтому использовался USB-привод.

    Зарегистрируйте сервер в Центре поддержки HPE, используя его серийный номер. Если вы заходите в Центр поддержки первый раз, вам нужно будет зарегистрироваться в службе HP Passport (она дает доступ ко всем ресурсам HP).

    После регистрации вам станет доступно скачивание Service Pack for ProLiant (SPP) — универсального средства настройки и обновления для большинства серверов HP ProLiant текущего и прошлых поколений. Скачать SPP можно здесь (Нажать ссылку «Получить программное обеспечение», файл 5ГБ у меня получилось скачать за 30 минут).

    Скачайте утилиту для создания загрузочных флешек HP USB Key Utility отсюда. Можете использовать также любую другую утилиту для создания загрузочных дисков/флешек из ISO-образа.

    C помощью утилиты запишите ISO-образ SPP на флешку.

    В моем примере мы будем устанавливать ОС Windows Server 2012R2, под нее вам потребуется драйвер RAID-контроллера B120i. Скачайте его здесь. Запишите драйвер на ту же флешку в папку с запоминающимся названием.

  • Драйверы для других операционных систем можно также найти на сайте HPE, их названия можно узнать из списка компонентов SPP (ищите по слову B120i).
  • Итак, у вас на руках флешка и диск с ОС. Начинаем настройку.

    Настройка RAID на сервере

      Подключите к серверу монитор, мышь и клавиатуру (используйте USB-порты на задней стороне сервера)

    Вставьте загрузочную флешку в USB-порт на лицевой стороне сервера

    Включите сервер и ждите, пока идет первоначальная инициализация (около 3-5 минут). Как выглядит этот процесс можно увидеть вот в этом реалистичном видео: youtu.be/ZVgCSp7G9R0, смотреть с 1:10 по 4:20

    Нас интересуют две строчки, которые появятся одновремено: HP Dynamic Smart Array B120i (инициализация должна дать результат 0 Logical volumes, то есть контроллер активен, но логические диски не созданы); а также приглашение внизу экрана нажать клавишу F11 для перехода в меню загрузки (Boot Menu) — нажмите F11 сейчас

    Когда под строчкой о контроллере B120i появится приглашение нажать клавишу F5 или Esc — нажмите Esc (для любого другого сервера ProLiant Gen8 или Gen9 здесь нужно было бы нажать F5 и перейти в SSA, а далее следовать этой же инструкции)

    Появится список возможных загрузочных устройств, нажмите клавишу с цифрой, обозначающей USB Drive (у меня это была цифра 3)

    Дальше появится экран с мигающим круглым логотипом HP, а после него — экран выбора варианта загрузки:

    Выберите Interactive mode

    Ждите некоторое время (около минуты вы будете видеть только обои рабочего стола и курсор)

    Принимаем условия лицензионного соглашения и жмем Next

    На появившемся первом экране графической оболочки смело жмем на средний пункт — HP Smart Storage Administrator (SSA)

    Когда SSA загрузится, отправляйтесь в настройки RAID

    Нажмите Create Array:

    Выберите диски, из которых хотите создать RAID-группу. Я выбрал все 4 доступных диска — Select All:

    На следующем экране я выбрал RAID 1+0, остальные настройки оставил как есть, и нажал Create Logical Drive:

    Следущий экран покажет итоги наших настроек, принимаем их и возвращаемся в главный экран SSA. Там нажимаем кнопку Set Bootable Logical Drive/Volume

    Выбираем созданный нами логический диск как загрузочный:

  • Все, выходим из SSA и снова попадаем на первый экран
  • Обновление программных компонентов сервера (прошивок)

      Теперь рекомендуется обновить прошивки, т.к. с момента выхода сервера с фабрики могло пройти много времени. Запускаем инструмент Firmware Update (левый пункт в меню)

    Даем инструменту автоматически проверить текущие версии прошивок и предложить варианты обновления:

    Соглашаем на все предложенные варианты (они сразу помечены Selected). Рекомендуемый в низу списка вариант (помечен Force) можно и пропустить, если вы не уверены, что он вам нужен. Жмем Deploy.

    Инструмент некоторое время обновляет прошивки (Deployment in progress) и потом предлагает осуществить перезагрузку, соглашаемся

  • Теперь наш сервер полностью готов к установке ОС.
  • Установка ОС Windows Server 2012R2

      Подключаем внешний DVD-привод с диском Windows Server и включаем сервер. Он автоматически загрузится с DVD.

    Следуя обычными шагами в начале установки Windows, мы дойдем до шага с выбором места для установки ОС. Windows не содержит в себе драйверы для контроллера B120i, поэтому скормим установщику драйверы с нашей флешки (DVD-привод на время подключения флешки в порт на лицевой панели можно отключить)

    Выбираем место расположения драйвера на флешке и собственно драйвер

    Теперь установщик видит свободное место, из которого можно сделать раздел кнопкой «Создать». Создаем раздел, выбираем его для установки Windows и жмем «Далее». Дальше установка пойдет как обычно.

    Вот и всё. Надеюсь, эта инструкция будет полезна обладателям ProLiant ML10v2, которых в России уже несколько сотен и становится все больше. К сожалению, на русском языке эта инструкция раньше нигде не публиковалась, что могло вызвать затруднения при развертывании в отсутствии встроенных инструментов в самом сервере. Заранее приношу извинения за возможные неудобства.

    Да и, если вы приобрели ML10v2 и у вас что-то не получается с подготовкой загрузочной флешки, то напишите запрос мне в личные сообщения. Мы сможем выслать вам готовую загрузочную флешку, протестированную на нашем железе. В запросе укажите серийный номер вашего сервера.

    Источник

    Читайте также:  Как подключить принтер samsung scx 3405w через wifi к ноутбуку
    Поделиться с друзьями
    КомпСовет
    Adblock
    detector